LDH 100

Oil humidity sensor

LDH 100

  • Continuous condition monitoring of oils and air
  • Two analogue outputs for relative moisture and temperature
  • High pressure rating
  • Quick installation via process connection

Technical data

Number of inputs and outputs

Number of analogue outputs: 2

Process connection

G 3/4

Media

Mineral oils; synthetic esters; biodegradable oils; air

Tank pressure [bar]

50

Medium temperature [°C]

-40-105

Operating voltage [V]

9-33 DC

Current consumption [mA]

< 25

Protection class

III

Reverse polarity protection

No

Number of inputs and outputs

Number of analogue outputs: 2

Total number of outputs

2

Number of analogue outputs

2

Analogue current output [mA]

4-20

Max. load [?]

8; ((Ub – 8) x 25)

Resolution of analogue output

φ: 1% / T: 0,1 K

Measuring range [°C]

-20-120

Accuracy

φ: ± 3 % / T: ± 2 %

Response time [s]

1,3

Ambient temperature [°C]

-40-85

Storage temperature [°C]

-40-85

Max. relative air humidity [%]

100

Protection

IP67

EMC

EN 13309

IEC 61000-6-2: 2005

IEC 61000-6-4: 2006 + AMD1: 2010

Vibration resistance

Test following DIN EN 60068-2-6

MTTF [years]

90

Weight [g

176,5

Materials (wetted parts)

Aluminium; HNBR; polyurethane resin; epoxy resin

Process connection

G 3/4

Remarks

Accuracy values expressed in percent refer to the measuring span

Notes

For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).

Pack quantity

1 pcs.

Connection

Connector: 1 x M12

Contact

Interested in our offer?

Write to us

Petro Bratko
Petro Bratko
Key Account Manager
+48 662 022 128
+48 (12) 362 97 66
pbratko@amcvibro.com


    "By submitting this form, I consent to the processing of my personal data by AMC VIBRO Sp. z o.o. with its registered office in Krakow at Pilotów 2E Street, as personal data administrator, for marketing purposes, including receiving commercial information sent to my email address by AMC VIBRO on its own behalf".


    *required fields